Lab Instrumentation

Labconco Corporation, U.S.A

Freeze Dryers / Lyophilizers - Your samples are valuable

Complete range with condenser capacity from 2.5L to 18L with all possible accessories including automatic vial stoppering under vacuum.

  • HCFC/CFC-free refrigeration system to cool collector to -50° C (-58° F)/-84° C/ -110° C.
  • Compact benchtop design/Floor models with a small footprint.
  • Real time display of collector temperature, vacuum level and optional End-Zone™ end point detection system.
  • Maintenance alert settings include vacuum pump oil change, refrigeration cleaning, total operating hours and line voltage offset.
  • Moisture sensor that prevents refrigeration or vacuum start-up when moisture is detected in the drain line.
  • Hot gas defrost with auto shut off at +60° C (+140° F).
  • Data logging stores and displays data in table or chart format and may be exported via USB or Ethernet.

Glassware washers - The real mates for all your washing needs

For washing & cleaning of any kind of laboratory wares with complete automation.

Designed to efficiently wash and dry a wide range of labware, including narrow-neck items.

  • Users have complete control over washing parameters and settings.
  • Capable of reaching a maximum wash temperature of 93°C (199°F), with a steam generator that produces hot vapor to eliminate stubborn contaminants from labware.
  • Adjustable setpoints for parameters such as temperature, fill volume and detergent dispensing.
  • Equipped with an electronic door latch featuring SpeedVent Technology for faster drying.
  • Aluminium-backed insulation paired with a fiberglass thermal blanket ensures efficient thermal management.
  • Water and detergent are distributed through spindles, ensuring thorough cleaning of even the innermost sections of glassware.
  • Includes 9 pre-set programs: RINSE ONLY, PLASTIC, GLASS, GLASS PLUS, LIFE SCIENTIFIC, ANALYTICAL, DRY ONLY, ECO WASH & CLEAN WASHER. Allows for up to 200 custom user-defined programs.

Biosafety cabinets

No one understands Biosafety better than us

NSF49 certified class II cabinets in A2/B2 types & a unique 8 C-type cabinet with unmatchable features. [can be used as A2 or B2 as & when required]

  • Real-Time Filter Life Indicator:

Instantly check the remaining filter life with our convenient line-of-sight display.

  • Warning & Alarm Systems:

Receive timely alerts when filter life decreases to 20%, ensuring proactive maintenance.

  • Smart ECM Motor:

The ECM motor automatically adjusts to varying filter loads, maintaining consistent airflow without the need for human or technical intervention throughout the filter's lifespan.

  • Line-of-Sight Display:

Enjoy a user-friendly experience with our interior-mounted, full-color LCD information center featuring the intuitive MyLogic OS for easy navigation.

  • ADA Compliance:

Features an ADA-compliant touchpad control located on the right-hand side post, allowing for manual activation of the blower, lights, timer, electrical receptacles and audible alarm mute, as well as menu selection.

Vacuum concentrator- accurate concentration of your samples

Unique technology that combines centrifugal force, vacuum & heat to speed up your sample evaporation.

  • Microprocessor-Controlled System with Heat and Vacuum Settings enabling programmable run time from 1 to 999 minutes, with heat settings from OFF to HI (100°C), adjustable in 1-degree increments. Optional Heat Boost function with heat time adjustable from 1 to 999 minutes.
  • Memory capable of storing 1 to 9 programs.
  • Control panel includes: RUN/STOP button, PREHEAT button, optional HEAT BOOST button, set point SELECT button, increase/decrease buttons and Quick-Start™ buttons.
  • LCD screen displays program number, actual and set point temperatures, heater time remaining, run time remaining and optional Heat Boost activation.
  • Quick-Stop™ System stops the vacuum pump, opens a valve to bleed air into the chamber and halts the rotor within seconds when the RUN/STOP button is pressed or time expires.
  • Automatic vacuum release valve prevents sample loss by releasing vacuum before the rotor stops and during power failures.
  • Built-in vacuum delay allows the rotor to reach full speed before applying vacuum.
  • Audible alarm signals the completion of the programmed run time.
  • Durable brushed stainless steel and glacier white, powder-coated steel exterior with blue accents.
  • Rear electrical receptacle for accessory vacuum pump connection.

The unique Refrigerated vacuum concentrators

Cutting edge technology designed to rapidly concentrate multiple small heat-sensitive samples. (For eg. RNA or Proteins)

  • The only concentrator available that integrates both a refrigeration system cooling to -4°C and a heater warming to +100°C, allowing users to achieve precise set point temperatures in one-degree increments.
  • Chemical resistant diaphragm vacuum pump with displacement capacity of 57 L /min.
  • HCFC/CFC-free refrigeration system to cool chamber to -4° C Sensor that reads chamber temperature.
  • Microprocessor-controlled programming for “Temperature 1” from -4° C to +100° C, “Temperature 1” time from 1 to 999 minutes or indefinite,
  • “Temperature 2” from -4° C to +100° C, and “Temperature 2” time from 0 to 999 minutes or indefinite. Memory stores 1 to 9 programs.
  • Centrifugal motion provided by a brushless motor capable of achieving up to 1725 rpm.
  • Control panel with RUN/STOP button, PREHEAT/COOL button, set point SELECT button, increase/decrease buttons and Quick-Start™ buttons.
  • Quick-Stop™ System stops vacuum pump, opens valve to bleed air into the chamber and tops the rotor within seconds after time expires or RUN/STOP button is pressed.
  • Automatic vacuum release valve prevents sample loss by releasing vacuum before the rotor tops and during power failures.
  • Built-in vacuum delay allows the rotor to reach full speed before applying vacuum.
  • Audible alarm to signal completion of set point run time.

Balance enclosures, bulk powder, equipment enclosers

Now contain airborne powders & particulates with these special enclosures.

XPert Filtered Balance Systems ensure user protection by effectively containing powders and particulates during weighing procedures. The built-in blower and HEPA exhaust filter, located in the upper plenum, save space compared to a separate exhauster, while isolation supports reduce blower vibration.

  • Available in 23" or 30" deep interiors to accommodate large micro and analytical balances.
  • Ergonomic air foil with aerodynamic Clean-Sweep airflow openings for efficient airflow.
  • Upper dilution air supply for optimal containment.
  • Upper containment sash foil and zone-perforated rear baffle for enhanced airflow management.
  • Side-entry air foils improve containment at the entry points.
  • Exhaust HEPA filter with 99.99% efficiency for particles as small as 0.3 microns.
  • True bag-in/bag-out filter disposal system for safe and easy filter replacement.
  • Built-in blower with dynamically-balanced, vibration-isolated motorized impeller.
  • Intrinsically safe design with negative pressure containment.
  • Equipped with a Minihelic pressure gauge for monitoring airflow.
  • Space-saving design eliminates the need for a separate filtered exhauster.
  • Upper diffuser screen for even airflow distribution.
  • Quiet operation, producing sound levels between 48-66 dB(A), depending on airflow.
  • Constructed with a glacier white and gray, dry powder epoxy-coated aluminum frame, steel rear plenum and baffle – no unreliable plastic-to-plastic bonding used.
  • Pre-wired fluorescent lighting with dedicated switches for both blower and light.
  • Speed control for precise airflow adjustments.
  • 1/4" thick tempered safety glass front sash and sides for robust containment.
  • Sash opening options of 9.4" or 12.0" for varied access needs.
  • Ergonomically designed, 10-degree angled, hinged sash that pivots upward, locks for loading and includes a wiping seal to prevent contamination.
  • Two utility ports for added convenience.
  • Particulate containment independently verified by SafeBridge Consultants, Inc.

Dry evaporators, concentrator & cold traps

Unique technology for concentration of large samples without using a conventional water bath. End point determination is also possible.


  • RapidVap systems accelerate evaporation through the combined use of nitrogen blowdown, vortex motion and heat.
  • Teflon-Coated Aluminum Block: Holds up to 48 tubes of varying volumes.
  • Powder-Coated Aluminum Base: Durable construction with an acrylic/PVC thermoplastic upper housing and glass lid.
  • Dual Lid Clamps & Phenol-Free Gasket: Ensures a secure seal.
  • PTFE-Coated Chamber: Chemically resistant for long-term use.
  • Microprocessor-Controlled System: Offers programmable vortex speed (0–100%), heat (up to 100°C) and time (1 to 999 minutes) with memory to store 1 to 9 programs.
  • Nitrogen Clusters: Configurable for 2, 4, 6, or 8 active nitrogen clusters.
  • LCD Display: Shows program number, vortex speed, temperature, time remaining and active nitrogen clusters.
  • Control Panel: Includes RUN/STOP, PREHEAT/END ALARM buttons, a VACUUM RELEASE button and adjustment controls.
  • Belt-Driven, Brushless DC Motor: Provides smooth variable-speed power for vortex motion, reaching up to 500 RPM.
  • Safety Alarms: Audible/visual alarms and automatic shutdown for timed endpoints and overheating, detected by temperature sensors in the heater and block.
  • Nitrogen Inlet Hose: ¼” ID for efficient gas delivery.
  • Chemical Isolation: All mechanical components are protected from chemical fumes and vapors.

Nanotechnology enclosers

Specialty balance enclosures which are designed for nanoparticulate capture, providing particulate containment & protection against potential occupational carcinogens.

  • Nano enclosures offer superior user protection by containing hazardous powders and particulates during procedures such as nanoparticle manipulation and dry powder chemical handling.
  • Air Filtration: Room air is drawn into the enclosure, passing through a 99.999% ULPA exhaust filter before being released back into the laboratory or cleanroom.
  • Easy Maintenance: The enclosure features stainless steel interior sides, a removable baffle, a removable air foil and an integral work surface, all of which are designed for easy cleaning.
  • Superior Particulate Containment: The enclosure maintains particulate levels at less than 20 nanograms per cubic meter, as verified by SafeBridge Consultants, Inc.
  • Quick Clean-Up: Perimeter scan testing detects average tracer gas levels of 0.05 ppm or less, surpassing ASHRAE 110 standards, with a fast 5-minute dilution time.
  • ISO Certification: It achieves airborne particulate cleanliness under both positive and negative pressures, surpassing ISO Class 5 (equivalent to Class 100) and achieving ISO Class 4 standards.
  • Leak Testing: Each unit is factory leak-tested using a mass spectrometer and helium pressurization at 1 inch of water gauge. No detectable leaks exceed 1 x 10⁻⁶ ml/sec.
  • Filter Integrity: The enclosure includes inlet and outlet HEPA or ULPA filters to prevent contaminants from entering or leaving the glove box. A test port is also provided for challenging the filter integrity.
  • Safe Filter Disposal: Equipped with a true Bag-In/Bag-Out Filter Disposal System for secure and safe filter removal and replacement.
  • Real-Time Monitoring: The LCD display provides real-time data on volume dilution rates (CFM), air changes per minute (ACM), and main chamber pressure (inches of water).
  • Adjustable Airflow: A built-in blower with speed control supports airflow rates from 15 CFM to 85 CFM.
  • Enhanced Visibility: The large viewing area, measuring 36" wide by 27.6" high, maximizes visibility with a 3/8" thick laminated safety glass window.
  • Space-Saving Design: Inner and outer transfer chamber doors pivot upward, are counterbalanced and feature quick-latch mechanisms for ease of use.

Ductless fume hoods

  • With special carbon filters which adsorb / treat chemical fumes and vapors without the need for external ducts.
  • Featuring special carbon filters designed to adsorb and treat chemical fumes and vapors, eliminating the need for external ducts.
  • These hoods are industrially recognized for effectively removing harmful or unpleasant concentrations of organic solvents, formaldehyde, acid gases, ammonia and radioisotopes from laboratories.
  • Patented slotted rear baffle: Enhances horizontal laminar airflow, ensuring fumes and vapors are safely drawn to the back of the enclosure, reducing turbulence and maintaining containment.
  • Organic chemical vapor sensor: Continuously monitors for chemicals breaching the filter, ensuring operator safety.
  • Digital interface: Provides real-time airflow and filter status, with touchpad controls for ease of operation.
  • Ergonomic angled sash: Designed for comfort and ease of use.
  • Durable construction: Features an epoxy-coated aluminum frame and a steel rear baffle and plenum for enhanced durability.
  • Patented Upper Dilution Air Supply: Ensures optimal air dilution within the enclosure.
  • Advanced ECM (Electronic Commutated Motor): Operates more efficiently and quietly than conventional motors, promoting energy savings and an ergonomic work environment.
Scroll to Top